Prove your wall design with data.

The R-values, fire performance, and moisture behavior needed for residential spec. Embodied carbon numbers that stand up in an LCA review.

Specifications & Testing Data

Attribute Value

R-value

R-3.0 to R-3.4 per inch

Fire rating

Class A (ASTM E84, no added retardants)

Compressive strength

≈ 40–80 psi (density-dependent)

Density

18–24 lb/cu ft (installed)

Vapor permeance

Highly vapor-permeable; hygroscopic buffering

Embodied carbon

−2 lbs CO₂e per 1 lb installed

Set time

45–60 minutes (initial); full cure 7–14 days

Placement method

Poured into standard stud framing

Code reference

2024 IRC Appendix BL — Hemp-Lime Construction

Full test reports (ASTM E84, ASTM C518, ASTM C39, third-party LCA) available on request via the CAD/BIM form below.

Request CAD / BIM Files & Full Spec Package

Spec package request

We’ll send DWG wall-assembly details, a Revit family, the full spec sheet, and test reports.

Download the Biofill™ B2B Info Sheet

Enter your name and email to access this download. We’ll also send it to your inbox.

No spam. Unsubscribe anytime.

Download the Biofill™ Homeowner Handout

Enter your name and email to access this download. We’ll also send it to your inbox.

No spam. Unsubscribe anytime.

Download the Pre-Pour Trade Checklist

Enter your name and email to access this download. We’ll also send it to your inbox.

No spam. Unsubscribe anytime.

Download the BIND/R™ Safety Data Sheet

Enter your name and email to access this download. We’ll also send it to your inbox.

No spam. Unsubscribe anytime.

Download the UNL Testing Report

Enter your name and email to access this download. We’ll also send it to your inbox.

No spam. Unsubscribe anytime.

Request Documents

Enter your name and email to get the installation guide starter pack.

No spam. Unsubscribe anytime.

Download the Biofill™ Project Submittal Template

Enter your name and email to access this download. We’ll also send it to your inbox.

No spam. Unsubscribe anytime.